New Technology ultraclear
Self-cleaning Double
Glazed Units
Light Transmission
(Vision Clarity) 85%
Self-cleaning Double
Glazed Units
Light Transmission
(Vision Clarity) 75%
Currently nearly all double glazed units are
constructed with Low E glass (low emissivity) which
has a noticeable tint. Our new Ultra Clear Low E
Units reduce the visible tint effect and increases the
Daylight/ Solar Factor and in appropriate conditions
may reduce the heating energy requirement.
SlimLite Standard

0131 551 2931
mail@slimliteglass.co.uk
Slimlite Double Glazed Units
Certification - U Values
Sound Reduction & U-Values
Timber Windows
Sash & Case
Reproduction Crown Glass
Construction Guide

Further Information
Emissivity Glass
Condensation
Glazing Method
Self Cleaning Double Glazing
Warm Edge Technology
Insulation U-Value
Heat Loss - Timber Windows
Building Regulations
Standard Double Glazed Units
Guarantees
Kevin McCloud - Period Drama
Solar Factor
Breakdown or Misting
Inert Gases
Glazing Bar & Astragal Detail

Glazing Method


Measuring:
Units should be measured to allow approximately 1mm to 1.5mm clearance all round where the rebate depth is 7mm. Allowance should be made where the opening is not perfectly rectangular. Where the rebate depth is in excess of 7mm, additional clearance can be allowed, but always ensuring that the sight line of the perimeter seal is below the sight line of the back rebate.

Glazing Timber Fore putty
top-windowsAll rebates should be clean and clear of minor obstructions and brushed cleaned and primed. The rebate should be bedded with a non hardening compound (butyl) to provide a bed between the back rebate and glass of approximately 1mm to 1.5mm. The unit should be placed into bedded opening and pressed equally around the perimeter until the 1mm to 1.5mm back bed is obtained.

However whilst the back bedding should be a non hardening compound such as butyl commonly used, silicon is sometimes used but mainly on metal windows.

The unit should be held in position by sprigs, which are thin metal shaped diamonds which are fixed into the rebate with a sprigging gun.

The use of a sprigging gun ensures that the diamond sprig is less than 1mm from glass, and prevents any scratches to glass surface. The sprig should be set at 150mm centres or as necessary for small panes.

The fore putty should be carried out with Linseed Oil Putty or Steel Sash Putty for metal windows, as BS6262 to the rebate depth sight line or just below to allow for paint finish line over putty. Putty should not be painted for at least seven days. The minimum fore putty on rebate width should not be less than approximately 6mm. The function of fore putty is to protect the frame by shedding the water from the frame, and protect the double glazed unit from ingress of water which will cause unit breakdown.

It is important that the fore putty should be brushed with a fine duster brush to ensure that there is a good seal on the putty against the glass, and painting should overlap the foreputty by approximately 2mm to provide an important final seal.

Glazing Timber Beads
All rebates should be clean and clear of obstructions, brushed clean and primed. The rebate should be bedded with non hardening compound (Butyl) to provide a bed of approximately 2mm between the glass and back rebate. The unit should be placed against the bedded back rebate and pressed equally around the perimeter until the 2mm back bed is obtained and only trimmed flush when glazing has been completed.

The rebate width should then be bedded with non hardening compound to obtain a very thin bedding not exceeding 2mm or gun grade which has a much thinner consistency. The timber bead which should be angled to provide a water shed and should be bedded against the glass by applying the compound to the front edge of the bead in sufficient quantity to prevent voids when fitted against the glass and excess trimmed, matching the water shed angle of the bead.

The finished height of the bead should be 2mm below the back rebate height to allow the painter to paint over the trimmed water shed angle of the compound to match the angled bead. The paint finish is important to provide protection against the rain and sun and the compound should be allowed to cure for at least 7 days before painting, and within 28 days.

Note

Where timber beads are to be pinned into the rebate width is particularly narrow the beads should be pre-drilled with a very fine drill.

Glazing Method
Slimlite Self Cleaning Double Glazed Units are supplied with taped perimeter edges for protection and safe handling and glazing. Slimlite is unaffected by Linseed Oil Putty. Linseed Oil putty has proved to be satisfactory over a long number of years and provided it is applied correctly as mentioned above should last a lifetime. It is necessary to paint over the putty at least every 5 years inland and 3 years in coastal areas. When putty cracks it is because of lack of paint protection.